  • Differences between internal and external storage pressures of heptafluoropropane
    categories of news:Corporate news   Author:handler    Published on:2016-12-194    Text:【big】【medium】【small

    The gas fire extinguishing system is divided into two types: pipe network and no pipe network. The pipe network includes internal storage pressure and external storage pressure. Today, we will talk about the differences between the internal storage pressure and external storage pressure of HFC-227ea.

    First, transmission distance:

    In general, the transmission distance of 2.5mpa pressure class pipeline is less than or equal to 32m, the transmission distance of 4.2mpa pressure class pipeline is less than or equal to 55m, and the transmission distance of 5.6mpa pressure class pipeline is less than or equal to 80m. The transmission distance greatly limits the application of HFC-227ea fire extinguishing system. The birth of external storage pressure is a good solution to solve this problem. The system action, fire extinguisher group, fire extinguishing agent group by special inflator cylinder group according to its stamping and conveying of HFC-227EA reagent design pressure is 4.2MPa, the maximum transport distance can be more than 240m.

    Here we look at the parameters of external storage pressure:

    According to the current national standard, the filling density of HFC-227ea fire extinguishing system with internal storage pressure is: 2.5MPa system should not be greater than 1120kg/m3 (steel welded gas cylinder); 4.2MPa system shall not be greater than 950kg/m3 (steel welded gas cylinder); 5.6MPa system should not be larger than 1080kg/m3 (steel seamless cylinder). 4.2MPa external storage pressure system shall not be greater than 1250kg/m3.

    Technical parameters:

    System main technical parameters

    System implementation standard

    Q/RXF 1-2014

    Storage pressure (20℃, MPa)

    0.3

    Extinguishing agent cylinder group volume (L)

    90

    120

    150

    180

    System injection time (s)

    ≤10

    Maximum filling rate of extinguishing agent(Kg/m3

    1250

    Operating temperature of the system (° C)

    0~50

    System working pressure (20℃) (MPa)

    4.2

    System maximum working pressure (MPa)

    5.3

    Temperature (℃)

    pressure Mpa (20 ° C)

    Power supply

    Design temperature

    Service temperature

    Fire extinguishing agent bottle group

    Nitrogen drive bottle set

    Main electricity

    Backup power

    0~50

    0~50

    0.3

    13.5

    AC

    220v

    DC

    24V

     

    Bottle group name

    Model Specification (L)

    Storage pressure (20℃)

    Nitrogen starting bottle set

    8L

    6MPa

    Nitrogen power cylinder set

    70L

    13.5MPa

    Fire extinguishing agent bottle group

    90

    120

    150

    180

    0.3MPa

    Finally, the nitrogen power bottle group is added to the external pressure storage system, which increases a pushing pressure to the delivery of the agent, so the transmission distance is relatively long.

    The above articles are organized and published by Guangzhou Rong 'an Fire Equipment Co., LTD.

    Share with:
    Number of clicks:10437  Update time:2016-12-19  【Print this page】  【CLOSE

Copyright © 2015   www.gzrongan.net    Guangzhou Rong 'an Fire Equipment Co., LTD   All rights reserved

Contact: Mr. Chen   Phone:13928768802   Mr. Huang   Phone:13711155165 Tel:020-31143089   Fax:020-31143992   Email:1851885478@qq.com   Address: 15 Yongfeng Road, Shawan Town, Panyu District, Guangzhou City, Guangdong Province  Registration license No. :粤ICP备16114979号

PC | Mobile